1. Surveillance Gadgets For Sale
  2. sku: 7626673069118772
  3. INTERLOGIX CR.D1300

INTERLOGIX CR.D1300 Ifs Point Data Transceiver RS-485 2-WIRE

Cr.d1300 Interlogix D1300 Ifs Rs-485 2-wire Point-to-point Data Transceiver

( Brand: Interlogix ), ( Manufacturer Part Number: CR.D1300 ), ( Type: Other ), ( Connectivity: Wired )

Review INTERLOGIX D1300 Ifs 2-wire Point to Data Transceiver

The **Interlogix CR.D1300 (D1300 IFS RS-485 2-Wire Point-to-Point Data Transceiver)** is a robust, high-performance communication module designed to facilitate seamless data transmission between security systems, access control panels, and other intelligent building technologies over a reliable RS-485 serial interface. Engineered for demanding environments, this compact yet durable transceiver operates in a **2-wire point-to-point configuration**, eliminating the need for complex wiring schemes while ensuring stable and secure data exchange between devices. Ideal for integration with Interlogix s IFS (Intelligent Fire & Security) architecture, the D1300 supports bidirectional communication at speeds up to **115.2 kbps**, making it perfectly suited for applications requiring real-time monitoring, alarm signaling, and control command relay between fire alarm systems, access control readers, and other security infrastructure components.

Built with reliability in mind, the CR.D1300 features **industrial-grade construction**, including a rugged metal enclosure that protects against environmental hazards such as dust, moisture, and temperature fluctuations, ensuring consistent operation in both controlled and harsh settings. Its **RS-485 interface** provides long-distance communication capabilities extending up to **1,200 meters (3,937 feet) per segment** while maintaining signal integrity through differential signaling, which minimizes interference from electromagnetic noise. The transceiver supports **half-duplex communication**, allowing multiple devices to share the same communication line without signal collision, making it an efficient solution for distributed security networks where wiring complexity must be minimized.

The D1300 is fully compatible with **Interlogix s IFS protocol**, enabling seamless integration with a wide range of security and building management systems, including fire alarm control panels, access control systems, and video surveillance platforms. Its **2-wire design** simplifies installation by reducing the number of required conductors, lowering labor costs and installation time while maintaining high performance. Additionally, the module includes **diagnostic LEDs** for easy troubleshooting, allowing technicians to quickly identify connection status, data flow, and potential communication issues. Whether deployed in commercial buildings, industrial facilities, or large-scale infrastructure projects, the CR.D1300 ensures dependable, low-latency communication between critical security devices, enhancing overall system reliability and operational efficiency.

For security professionals and integrators seeking a **high-performance, low-maintenance communication solution**, the Interlogix CR.D1300 stands out as a versatile and dependable choice. Its combination of **industrial durability, long-range connectivity, and IFS protocol compatibility** makes it an essential component for modern security networks where seamless data transfer is paramount. Whether used in new installations or retrofitted into existing systems, this transceiver delivers the performance and reliability required to maintain secure and efficient communication between critical security devices.

The **Interlogix CR.D1300 (D1300 IFS RS-485 2-wire Point-to-Point Data Transceiver)** is a communication device designed to facilitate secure, encrypted data transmission between security systems and remote locations. Below is a detailed breakdown of its pros and cons, followed by a conclusion and recommendation.

---

### **Pros of the Interlogix CR.D1300**

1. **Secure Encryption**

The device supports **AES-128 encryption**, ensuring that data transmitted between security systems (such as control panels and remote devices) is protected from unauthorized access or tampering. This is critical for preventing hacking or signal interception in security applications.

2. **Point-to-Point Communication**

It operates on a **2-wire RS-485 bus**, allowing direct communication between two devices (e.g., a control panel and a remote sensor or keypad) without the need for a complex network infrastructure. This simplifies wiring and reduces installation complexity.

3. **Compatibility with Interlogix Systems**

As part of the Interlogix ecosystem, the CR.D1300 integrates seamlessly with other Interlogix security products, such as the **D1300 series control panels** and **IFS (Interlogix Fire System) devices**. This ensures smooth interoperability and reduces compatibility issues.

4. **Long-Distance Communication**

RS-485 technology is designed for **long-distance communication** (up to several kilometers, depending on wiring and environmental conditions), making it suitable for large properties or distributed security systems.

5. **Low Power Consumption**

The device is designed to operate efficiently, reducing power draw on the system. This is beneficial for battery-backed or remote installations where power management is important.

6. **Reliable Data Transmission**

RS-485 is a **robust communication protocol** that is less susceptible to electrical noise and interference compared to other methods like RS-232. This improves the reliability of data transfer in industrial or noisy environments.

7. **Easy Installation**

The 2-wire setup minimizes wiring complexity, and the device is typically plug-and-play compatible with supported systems, reducing installation time and potential errors.

8. **Support for Multiple Protocols**

Depending on the application, the CR.D1300 can support various communication protocols used in security systems, ensuring flexibility in system design.

---

### **Cons of the Interlogix CR.D1300**

1. **Limited to Point-to-Point Only**

The device is **not designed for multi-drop or networked setups**. If you require communication between more than two devices, you would need additional repeaters or a different communication method (e.g., Ethernet or wireless). This can add complexity and cost.

2. **Dependence on Interlogix Ecosystem**

The CR.D1300 is optimized for **Interlogix products**. If your system includes non-Interlogix devices (e.g., third-party alarms or sensors), compatibility may not be guaranteed, requiring additional gateways or converters.

3. **Physical Wiring Limitations**

While RS-485 supports long distances, the actual range depends on factors like **cable quality, termination, and environmental conditions**. Poor wiring (e.g., unshielded cables in noisy areas) can degrade performance, requiring careful planning.

4. **No Built-in Diagnostics or Logging**

Unlike some modern security devices, the CR.D1300 may lack **built-in diagnostic tools or logging capabilities**. Troubleshooting communication issues could require additional equipment or manual testing.

5. **Potential for Latency**

In high-traffic or poorly configured setups, there may be **delays in data transmission**, which could affect real-time monitoring or alarm responses. This is less of an issue in simple point-to-point setups but could be problematic in more complex configurations.

6. **Limited Future-Proofing**

Security systems are evolving toward **IP-based and wireless communication**. The CR.D130ix s reliance on RS-485 may make it less future-proof if your system eventually transitions to more modern technologies.

7. **Cost of Additional Components**

If you need to extend the communication range beyond the device s capabilities, you may require **repeaters or amplifiers**, adding to the overall cost of the system.

8. **No Built-in Redundancy**

In a point-to-point setup, if the cable or the device fails, the entire communication link is disrupted. There is no built-in redundancy (e.g., backup communication path) to maintain connectivity.

---

### **Conclusion**

The **Interlogix CR.D1300 (D1300 IFS RS-485 2-wire Point-to-Point Data Transceiver)** is a **reliable, secure, and low-maintenance solution** for simple point-to-point communication in Interlogix security systems. Its strengths lie in **encryption, long-distance capability, and ease of installation**, making it ideal for applications where two devices need to communicate securely without the complexity of a network.

However, its **lack of support for multi-drop setups, dependence on Interlogix compatibility, and potential wiring limitations** may make it unsuitable for larger or more complex systems. Additionally, its **limited diagnostic features and lack of redundancy** could be drawbacks in mission-critical applications where uptime is paramount.

---

### **Recommendation**

**Buy the Interlogix CR.D1300 if:**

- You are working with an **Interlogix security system** and need a **secure, encrypted point-to-point communication link** between two devices (e.g., a control panel and a remote keypad or sensor).

- Your setup is **simple and does not require multi-drop or networked communication**.

- You prioritize **low wiring complexity and long-distance communication** in a controlled environment.

- Budget and system constraints make it impractical to adopt more modern (e.g., IP-based) communication methods.

**Avoid the Interlogix CR.D1300 if:**

- You need **multi-drop or networked communication** (consider RS-485 hubs or Ethernet-based solutions instead).

- Your system includes **non-Interlogix devices**, as compatibility may not be guaranteed.

- You require **advanced diagnostics, logging, or redundancy** in your communication setup.

- You anticipate **future expansion** that may require IP or wireless communication, as the CR.D1300 may become obsolete.

**Alternatives to Consider:**

- For **larger or more complex systems**, evaluate **RS-485 multi-drop solutions** or **IP-based communication modules** (e.g., Ethernet gateways).

- If **wireless communication** is an option, consider **encrypted wireless transceivers** (e.g., 802.15.4 or LoRa-based devices) for greater flexibility.

- For **modern security systems**, IP-based protocols (e.g., BACnet, Modbus TCP) may offer better scalability and integration with cloud platforms.

In summary, the CR.D1300 is a **solid choice for its intended purpose** but may not be the best long-term solution for evolving or complex security needs. Carefully assess your system requirements before purchasing.

Details:

part #: crd1300 prices

  • $49.95-$395.00

specifications surveillancegadgetgo:

  • brand: Interlogix
  • mpn: Cr.d1300
  • type: Other
  • connectivity: Wired

general surveillancegadgetgo:

  • condition: New
  • Home Surveillance > Home Surveillance Parts Accessories > Other Surveillance Parts Accessories

payments surveillancegadgetgo:

  • other
  • wallet: Google-pay
  • credit card: Mastercard

offer surveillancegadgetgo:

  • started: March 17, 2026
  • options: Ship-to-home
  • quantity: 1
  • sold: 0
  • availability: In Stock
  • best offers: True

returns surveillancegadgetgo:

  • policy: No Returns

shipping surveillancegadgetgo:

  • cost: $0.00
  • class: Standard
  • type: Fixed
  • transit: 3-8 Days
  • carrier: USPS
  • service: USPS Ground Advantage

seller surveillancegadgetgo:

  • city: Brookline, Massachusetts
  • # reviews: 8112
  • rating: 98.5%
type: other, connectivity: wired,
category: electronics > home surveillance > home surveillance parts accessories > surveillance parts accessories, sku: 7626673069118772,
Interlogix CR.D1300 Is Similar To:
surveillancegadgetgo logo
5 offers $49.95–$395.00 USD
  • New. Offer #1 priced at $49.95 + $8.00 shipping estimate = $57.95* total. The Interlogix D1300WDMB-R3 is designed for use with multimode optical fiber. The Interlogix D1300WDMB-R3 data transceiver provides point-to-point transmission of half-duplex (2-wire) EIA tri-state data signals over one optical fiber.+$8.00 shipping
  • New. Offer #2 priced at $395.00 + $16.45 shipping estimate = $411.45* total. D1315-24. Interlogix.+$16.45 shipping
  • Open box. Offer #3 priced at $85.00 + $25.35 shipping estimate = $110.35* total. Interlogix D1300 IFS (2-wire) Point-to-Point Data Transceiver (Open Box).+$25.35 shipping
  • New. Offer #4 priced at $99.99 + $0.00 shipping estimate = $99.99* total. New.FREE SHIPPING
  • New. Offer #5 priced at $285.10 + $2.99 shipping estimate = $288.09* total. Transparent to Data Encoding / Compatible with Major Data Protocols. Hot-Swappable Rack Modules.+$2.99 shipping

Copyright © surveillancegadgetgo.com